Installation and Operation ManualforIntelligence Dome CameraV1.1Please read the operation manual carefullybefore installing and using this unit
63. Setup of the Menu of the Dome Camera1. Basic Operation of the Menu1.1 Call preset 64 or call preset 1 twice within 4 seconds to enter themain menu
72.1.7 CAM DEFAULT SET: to reset default setup of camera.2.1.8 DOME RESET: to reset the dome camera.2.1.9 EXIT: to quit the main menu.2.2 DISPLAY SETU
82.3.7 WB SET: setup of white balance. ATW / INDOOR / OUTDOOR /ONEPUSH / AUTO / MANU2.3.8 MENU OF CAM: blank2.3.9 RETURN: return to MAIN MENU2.4 CONTR
92.5 CAMERA MASK SET2.5.1 MASK PRIVACY: ON/OFF2.5.2 MASK SHADE: BLACK/GRAY/WHITE2.5.3 MASK REGION: 6 or 2 privacy zonemasking.(only for part of camera
-10edit by CLOSE button. Operations under edit state can be seenlater.2.6.5 SET PATROL: to edit data for multi-points patrol. Select no. ofpatrol by P
11Both top and bottom lines display prompt and information of eachpatrol is displayed on the middle of the screen. Data of 2 Patrolpoints appears on o
-124. Setup of the Dome Camera1. Connection of the System1) The Systematic Drawing of the Dome CameraVideo frequencyMultiplexerMatrixKey PadMonitor1Mo
-13Figure 2b. Middle speed and low speed domeFigure 3As shown in Figure 2,3, SW1 is used to set address of the domecamera from 1 – 1023. The coding sw
-145 ON OFF ON OFF OFF OFF OFF OFF OFF OFF6 OFF ON ON OFF OFF OFF OFF OFF OFF7 ON ON ON OFF OFF OFF OFF OFF OFF OFF8 OFF OFF OFF ON OFF OFF OFF OFF OF
-15DIP status Normal Baud RateProtocolsDIP-1 DIP-2 DIP-3 DIP-4 DIP-5 DIP-6SAMSUNG ON OFF OFF OFF OFF ONB01 ON OFF OFF OFF OFF ONNEON ON OFF OFF OFF OF
SAFETY PRECAUTIONS
-163. Setup of the Baud Rate of Communication. As shown in Figure2,3 SW2 is used to set the protocol of communication and the baudrate used by the dom
-175. The Installation of the System1. Dimension of the Product2. The Style of Installationa) Wall InstallationFigure5b) In-Ceiling InstallationFigure
-18c) Product disposition overall sizeFigure 73. The step of high speed dome installs (taking wall-installingstyle as example)1) Unpacking the carton
-19Figure 10 Figure 11 Figure 125) Fix the pedestal in the aluminum alloy ball (Figure 11). Installthe ball on the bracket (Figure 12).6) Trip wire to
-207) Insert attachment plug in aluminum alloy into socket D2(Figure 15) . According the fig of D3 to connection. As show offig47 when dome identify t
-219) Based on the coding switches shown as Figure 2, set up theprotocol used by the camera and the baud rate as per the stateaccording to Table 2. Ch
-227) a step of operation.3) 4 bolts black coats which the inside lining squeeze out, takedown the inside lining black cover(Figure 21)4) Based on the
-23Figure 24 Figure 259) Fixes the support on the wall (Figure 26)10) Fixes the dome to the support aboveFigure 2611) System pilot wire after (Figure
-24(Figure 28)3) Take out system control wires from the bracket(Figure 29)4) Fixes the ball cover to the support above(Figure 30)5) System pilot wire
-256. Technical data table1. High speed balls cameras technologyPower supply AC24V 50/60HzPower consumption Indoor dome:15W Outdoor dome:35WSync syste
INDEX1.Important Safeguards------------------------------------------------------------12.Description of Functions -----------------------------------
-26Synchronization InternalPreset position 64Cruising track 6Pan scanning 360°programablyPan speed Maximum 80°/sPan range 360°continuouslyTilt range 0
-27Iris Auto/ ManualFocus Auto/ Manual16×optical18×optical22×optical23×optical27×opticalZoom Ratef=3.9 to63 mmf=4.1 to73.8 mmf=4 to 88mmf=3.6 to82.8 m
-28have it’s own menu, toopen/close the menuby the command “turnon the OSD”, and usethe command “turn offthe OSD”to open/closethe OSD)58 Digital Zoom
-29Protocol setup is wrongReset and SwitchON againBad connection of the videoPress to connect wellVague imagePower supply not enough ReplaceSelf check
-30electricity net. When the system is grounded separately, theresistance of down conductor should be ≤ 4Ω and the sectionalarea of down conductor sho
-31Appendix Ⅲ: RS485 Bus Basic Knowledge1. Characteristics of RS485 BusAs specified by RS485 standards, RS485 Bus is of half-duplexeddata transmission
-32120Ω1# 2# 3# 31#120ΩDA+B-A+ B-. . . . .. . . . .Main controllerFigure 33The connection of 120Ω termination resistor: The terminationresistor is rea
-33Figure 34In such circumstances the factory recommends the usage ofDR-HB16 RS485 distributor. The distributor can change the starconfiguration conne
-34Appendix Ⅳ:Wire Diameter and Transmission Distance Comparison ChartWire diameter (mm)TransmissionDistancefeet(m)Power [VA]0.8000 1.000 1.250 2.0001
-35Appendix Ⅴ : Wire Gauge Conversion ChartBare wirediametermetric size(mm)AWG(Approximate)SWG(Approximate)Bare wirecrosssectional area(mm2)0.050 43 4
-360.900 19 20 0.63621.000 18 19 0.78541.250 16 18 1.22661.500 15 1.76652.000 12 14 3.14202.500 4.90803.000 7.0683Table 9
CCTVSYSTEM
11. Points for Attention1. All the safety and operating instructions should be read before theunits is operated.2. This unit should be operated only f
26. The product should be indoor installedand operated to avoid rain and moisture.Do not use it in wet places. If outdoorinstallation is needed, the c
32. Description of FunctionsThe intelligent dome camera is a hi-tech CCTV product whichincorporates high-clarity color camera, panoramic speed-variabl
43. High Intelligent Degreea. Dome general functionsa. As much as 128 preset positions can be preset with powerlessmemoryb. The camera can scan horizo
54. Functions of the Camera (icons can be displayed on thescreen when the option DISPLAY of the camera is ON,Onlyfor 18×Camera)a. Description of the F